527 research outputs found

    Identifying and mitigating biases in EHR laboratory tests

    Get PDF
    AbstractElectronic health record (EHR) data show promise for deriving new ways of modeling human disease states. Although EHR researchers often use numerical values of laboratory tests as features in disease models, a great deal of information is contained in the context within which a laboratory test is taken. For example, the same numerical value of a creatinine test has different interpretation for a chronic kidney disease patient and a patient with acute kidney injury. We study whether EHR research studies are subject to biased results and interpretations if laboratory measurements taken in different contexts are not explicitly separated. We show that the context of a laboratory test measurement can often be captured by the way the test is measured through time.We perform three tasks to study the properties of these temporal measurement patterns. In the first task, we confirm that laboratory test measurement patterns provide additional information to the stand-alone numerical value. The second task identifies three measurement pattern motifs across a set of 70 laboratory tests performed for over 14,000 patients. Of these, one motif exhibits properties that can lead to biased research results. In the third task, we demonstrate the potential for biased results on a specific example. We conduct an association study of lipase test values to acute pancreatitis. We observe a diluted signal when using only a lipase value threshold, whereas the full association is recovered when properly accounting for lipase measurements in different contexts (leveraging the lipase measurement patterns to separate the contexts).Aggregating EHR data without separating distinct laboratory test measurement patterns can intermix patients with different diseases, leading to the confounding of signals in large-scale EHR analyses. This paper presents a methodology for leveraging measurement frequency to identify and reduce laboratory test biases

    The Role of Nonlinear Dynamics in Quantitative Atomic Force Microscopy

    Full text link
    Various methods of force measurement with the Atomic Force Microscope (AFM) are compared for their ability to accurately determine the tip-surface force from analysis of the nonlinear cantilever motion. It is explained how intermodulation, or the frequency mixing of multiple drive tones by the nonlinear tip-surface force, can be used to concentrate the nonlinear motion in a narrow band of frequency near the cantilevers fundamental resonance, where accuracy and sensitivity of force measurement are greatest. Two different methods for reconstructing tip-surface forces from intermodulation spectra are explained. The reconstruction of both conservative and dissipative tip-surface interactions from intermodulation spectra are demonstrated on simulated data.Comment: 25 pages (preprint, double space) 7 figure

    The use of direct geometry spectrometers in molecular spectroscopy

    Get PDF
    The advantages and disadvantages of the use of direct geometry spectrometers for molecular spectroscopy and catalysis studies are described. We show that both direct and indirect geometry INS spectrometers are important tools for the study of industrially relevant areas such as catalysis, proton conductors and gas separation. We propose a novel hybrid instrument, Cerberus, that would offer high sensitivity and high-to-reasonable resolution across the entire 'mid-infrared' spectral range that would effectively advance research in these areas
    • …
    corecore